Electrical Assembly
Item No. | Part No. | Description | Model410 | Model420 | Stocking Level |
---|---|---|---|---|---|
1 | 65073 | 24VAC secondary heat contactor | 1 | 2 | A |
2 | 29509 | 24VAC primary contactor | 1 | 2 | A |
3 | High-limit control service pack, 230 VAC, 445°F, blue (Before 12/2020) | 2 | 4 | A | |
3 | 175915-009 | Service pack - dual high limit control, 100-240 VAC, 445°F - Gen 1, blue sticker (12/2020 to BM2409010) - Gen 2, black triangle (BM2409011 and after) Note: Dates are production implementation dates. Gen 2 is newest design. - Gen 2 can replace a Gen 1. - Gen 1 cannot replace a Gen 2. | 2 | 4 | A |
4 | N/A see 140771 | Circuit breaker, 208-240 VAC, 60 A (discontinued, see item 11) | 1 | 2 | |
5 | N/A see 140771 | Circuit breaker with shunt, 208-240 VAC, 60 A (discontinued, see item 11) | 1 | 2 | |
5 | 154796 | Circuit breaker with shunt, 480 VAC, 30A | 1 | 2 | |
6 | 85698 | AIF PCB board common | 1 | 1 | A |
7 | 84134 | 208V 24V 50/60 75VA transformer w/ 24 in. wire | 2 | 3 | |
7 | 86087 | 240V 24V 50/60 75VA transformer w/ 24 in. wire | 2 | 3 | |
8* | 24347 | Xformers current sense assembly | 1 | 2 | A |
9* | ME90-008 | 12VDC coil 30A P&B T92 relay | 1 | 1 | A |
10* | 96146-001 | Xformer current sense element assembly | 1 | 2 | A |
11* | 140771 | Service Breaker Kit for UL 208/240V 60A | 1 | 2 | |
Recommended Parts: A = Truck Stock; B = Dist. Stock * = Not Shown |